<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Toronto Stucco &#38; EIFS Blog&#187; caulking</title>
	<atom:link href="http://torontostuccocontractor.com/blog/tag/caulking/feed/" rel="self" type="application/rss+xml" />
	<link>http://torontostuccocontractor.com/blog</link>
	<description>Information about Exterior Insulation Finish Systems for Home Owners</description>
	<lastBuildDate>Sat, 12 May 2012 17:38:53 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.2</generator>
		<item>
		<title>Maintenance Guide For EIFS (Stucco)</title>
		<link>http://torontostuccocontractor.com/blog/2012/02/maintenance-guide-for-eifs-stucco/</link>
		<comments>http://torontostuccocontractor.com/blog/2012/02/maintenance-guide-for-eifs-stucco/#comments</comments>
		<pubDate>Thu, 16 Feb 2012 13:28:10 +0000</pubDate>
		<dc:creator>Admin</dc:creator>
				<category><![CDATA[Intermediate]]></category>
		<category><![CDATA[airless finish]]></category>
		<category><![CDATA[bleach]]></category>
		<category><![CDATA[caulking]]></category>
		<category><![CDATA[demand products]]></category>
		<category><![CDATA[dirt]]></category>
		<category><![CDATA[discolouring]]></category>
		<category><![CDATA[drainage]]></category>
		<category><![CDATA[eifs maintenance]]></category>
		<category><![CDATA[finish coat]]></category>
		<category><![CDATA[flashing]]></category>
		<category><![CDATA[sealant]]></category>
		<category><![CDATA[stucco repair]]></category>
		<category><![CDATA[sureklean]]></category>
		<category><![CDATA[water damage]]></category>
		<category><![CDATA[water leak]]></category>
		<category><![CDATA[windlock]]></category>

		<guid isPermaLink="false">http://torontostuccocontractor.com/blog/?p=596</guid>
		<description><![CDATA[You&#8217;ve completed your stucco renovation, and hope the contractor did a good job. But did he leave you with any guidelines for maintaining your new wall system? Chances are slim that the contractor took a long-term interest in the condition of your home, but you should and we&#8217;ll show you how. Whenever possible, contact the [...]]]></description>
		<wfw:commentRss>http://torontostuccocontractor.com/blog/2012/02/maintenance-guide-for-eifs-stucco/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Caulking Integrity with Stucco</title>
		<link>http://torontostuccocontractor.com/blog/2011/01/caulking-integrity-with-stucco/</link>
		<comments>http://torontostuccocontractor.com/blog/2011/01/caulking-integrity-with-stucco/#comments</comments>
		<pubDate>Thu, 27 Jan 2011 04:02:35 +0000</pubDate>
		<dc:creator>Admin</dc:creator>
				<category><![CDATA[Beginner]]></category>
		<category><![CDATA[caulking]]></category>
		<category><![CDATA[eifs]]></category>
		<category><![CDATA[exterior insulation finish systems]]></category>
		<category><![CDATA[hardie board]]></category>
		<category><![CDATA[sealant]]></category>
		<category><![CDATA[stucco]]></category>
		<category><![CDATA[stucco wall]]></category>
		<category><![CDATA[t-111]]></category>
		<category><![CDATA[vinyl siding]]></category>
		<category><![CDATA[water proof]]></category>
		<category><![CDATA[windows]]></category>

		<guid isPermaLink="false">http://torontostuccocontractor.com/blog/?p=436</guid>
		<description><![CDATA[One of the primary reasons that EIFS (Exterior Insulation Finish Systems) has been targeted by insurance companies and cities is because of &#8220;failures&#8221; it has experienced around window and door openings. The problem lies primarily with improperly installed caulking failing (i.e. the wrong type being used), an integral part of all projects that no one [...]]]></description>
		<wfw:commentRss>http://torontostuccocontractor.com/blog/2011/01/caulking-integrity-with-stucco/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>The EIFS Lies Countinue</title>
		<link>http://torontostuccocontractor.com/blog/2009/12/the-eifs-lies-countinue/</link>
		<comments>http://torontostuccocontractor.com/blog/2009/12/the-eifs-lies-countinue/#comments</comments>
		<pubDate>Tue, 08 Dec 2009 19:13:37 +0000</pubDate>
		<dc:creator>Admin</dc:creator>
				<category><![CDATA[Hall Of Shame]]></category>
		<category><![CDATA[barrier eifs]]></category>
		<category><![CDATA[builders alert]]></category>
		<category><![CDATA[caulking]]></category>
		<category><![CDATA[drainage eifs]]></category>
		<category><![CDATA[eifs]]></category>
		<category><![CDATA[flashing]]></category>
		<category><![CDATA[mildew]]></category>
		<category><![CDATA[mold]]></category>
		<category><![CDATA[nc]]></category>
		<category><![CDATA[north carolina]]></category>
		<category><![CDATA[raleigh]]></category>
		<category><![CDATA[rot]]></category>
		<category><![CDATA[scott shepard]]></category>
		<category><![CDATA[tim oglesby]]></category>
		<category><![CDATA[wall systems]]></category>
		<category><![CDATA[weather barrier]]></category>

		<guid isPermaLink="false">http://torontostuccocontractor.com/blog/?p=286</guid>
		<description><![CDATA[Source: http://www.scottshepard.net/remaxil/modules/agent/agent.asp?p=pagecontent.asp&#38;nav=1&#38;pid=42&#38;acc=89890 It&#8217;s ironic this guy&#8217;s last name is Shepard, because he&#8217;s leading his clients astray. Even today, uninformed real estate agents, building inspectors and many others are posting and re-posting false information about EIFS. I just need to address a few of the issues with this article: 1) In 1994, moisture damage to the [...]]]></description>
		<wfw:commentRss>http://torontostuccocontractor.com/blog/2009/12/the-eifs-lies-countinue/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Window Lacking Flashing and Caulking</title>
		<link>http://torontostuccocontractor.com/blog/2008/11/window-lacking-flashing-and-caulking/</link>
		<comments>http://torontostuccocontractor.com/blog/2008/11/window-lacking-flashing-and-caulking/#comments</comments>
		<pubDate>Tue, 25 Nov 2008 16:48:16 +0000</pubDate>
		<dc:creator>Admin</dc:creator>
				<category><![CDATA[Hall Of Shame]]></category>
		<category><![CDATA[acrylic damage]]></category>
		<category><![CDATA[backer rod]]></category>
		<category><![CDATA[caulking]]></category>
		<category><![CDATA[flashing]]></category>
		<category><![CDATA[window]]></category>
		<category><![CDATA[window frame]]></category>

		<guid isPermaLink="false">http://torontostuccocontractor.com/blog/?p=69</guid>
		<description><![CDATA[Whoever installed the stucco around this window deserves to be sued. There are 3 things I immediately see wrong with this: There is no flashing over the window, this means that any water in behind the system (which likely isn&#8217;t drainage either) will become trapped in and around the window frame, causing mold and rot. [...]]]></description>
		<wfw:commentRss>http://torontostuccocontractor.com/blog/2008/11/window-lacking-flashing-and-caulking/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Protected: Proper Installation of Hose Bib and Fixtures Into EIFS</title>
		<link>http://torontostuccocontractor.com/blog/2008/11/proper-installation-of-hose-bib-and-fixtures-into-eifs/</link>
		<comments>http://torontostuccocontractor.com/blog/2008/11/proper-installation-of-hose-bib-and-fixtures-into-eifs/#comments</comments>
		<pubDate>Sun, 23 Nov 2008 02:56:45 +0000</pubDate>
		<dc:creator>Admin</dc:creator>
				<category><![CDATA[Advanced]]></category>
		<category><![CDATA[accessory]]></category>
		<category><![CDATA[backer rod]]></category>
		<category><![CDATA[caulking]]></category>
		<category><![CDATA[fixture]]></category>
		<category><![CDATA[hose bib]]></category>
		<category><![CDATA[wall penetration]]></category>
		<category><![CDATA[wood blocking]]></category>

		<guid isPermaLink="false">http://torontostuccocontractor.com/blog/?p=48</guid>
		<description><![CDATA[There is no excerpt because this is a protected post.]]></description>
		<wfw:commentRss>http://torontostuccocontractor.com/blog/2008/11/proper-installation-of-hose-bib-and-fixtures-into-eifs/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

