Synthetic Stucco – Why Weeping Holes Are Important

Synthetic Stucco (actually known as EIFS) is a popular cladding among both commercial buildings and residential homes in Northern climates because of it’s superior ability to insulate a wall and manage moisture. The moisture management comes primarily from 2 important components of EIFS:

  1. The weather barrier (typically trowel-applied) that acts as a back-up defense against any incidental moisture that gets past the outer barrier
  2. The drainage cavity created by geometrically defined insulation (read: insulation with grooves in the back) and strategically placed adhesive

There are a number of important details that need to be paid attention to, to ensure the system performs optimally. It’s important to note that the drainage system will work even if the details are screwed up to some degree, just not optimally. What we’ll focus on here is the weeping holes though.

Stucco Weeping Holes

Stucco Weeping Holes on a commercial building

Weeping holes are simply gaps in the caulking that is installed at the base of an EIFS wall. The EIFS can terminate 8″ above grade (per building code requirements), above another material (such as brick or stone) or at the joint between floors. EIFS should be terminated with a flashing that is tied into the weather barrier with the use of an EIFS tape, so that water is diverted away from the wall, out onto the exterior surface. Caulking is then installed between the flashing and the EIFS termination (the underside of the EIFS), with weeping holes every 24″ (or per manufacturer specifications).

The caulking prevents excessive wind-driven rain, and/or insects from entering into the EIF system from the bottom. The weeping holes provide adequate area for air flow and drainage of incidental water, while being small enough to act as a deterrent to insects. There’s actually a study floating around somewhere that concludes that the ventilation within an EIFS wall is enough to create an inhospitable environment for bugs to nest.

The lack of weeping holes when caulking is present is strangely common – whether by fault of the EIFS contractor being improperly trained (or maliciously lazy – is that an oxymoron?), a site supervisor lacking the knowledge, or inadequate inspection from the manufacturer. An EIFS wall without adequate drainage from the bottom may suffer from:

  • Precipitate buildup at the caulking
  • Inadequate air-flow for ventilation

Both of which will generally shorten the life of the EIFS wall itself. Will a general contractor who is on the job to ‘get it done and move onto the next’ care? Not likely. The EIFS wall probably won’t fail within the GC’s liability/warranty period, and they probably have backlash against the installer or supplier of the EIFS system regardless. It’s more about ensuring that EIFS countinue to be seen as a reliable, effective cladding for the sake of the future of the industry.

Oh, and the person who ends up owning or using the building. They’re important too.

EIFS Insulates and Controls Moisture Better Than Hardiboard, Brick, Stucco

The results of a Phase II U.S Depart of Energy study on EIFS (synthetic stucco) have been provided, and confirm what building professionals have known for years: EIFS insulates walls and manages moisture better than alternative building products including hardiboard, brick and (traditional) stucco. The study was done over the course of 3 years in the worst climate possibly — a mixed, coastal, Zone 3 (hot and humid) climate.

This puts EIFS as the front-runner for U.S President Obama’s stimulus package, which includes provisions to re-clad buildings with a more energy efficient siding. Add to these results the fact that EIFS is typically less expensive than alternative cladding products and has the widest range of design options (you can match ANY colour, there are multiple varieties of textures, and an unlimited possible designs via architectural mouldings), you have a clear winner among the siding options available for buildings today.

View EIMA’s executive summary of the study at: http://www.eima.com/pdfs/EIMA%20ORNL%20ExecSum%20Final.pdf